The meaning of E117
E117 tells you the heating pressure has climbed too high. Baxi's Duo-tec guide says the safety valve operates above 3 bar. You may well be able to clear this one yourself.
Codes can differ between models, so look at the fault table in your user instructions too. Village homes around Coton Park and Long Lawford can be more exposed in a cold snap, so frozen condensate pipes crop up there every winter.
Typical causes
In our experience, and in the manufacturer's own guidance, the usual causes are:
- The filling loop left open or letting water by
- Overfilling when topping up
- An expansion vessel that has lost its charge
Homeowner checks
1. Read the gauge for high pressure
If the gauge reads close to 3 bar, the pressure relief valve may already be letting water out through a pipe outside. With the heating off and the radiators cool, letting a little water out of a radiator bleed valve lowers the pressure. Keep a cloth handy and stop at about 1 to 1.5 bar. If the pressure creeps up again without you touching the filling loop, the filling loop may be letting water through or the expansion vessel may need attention, which an engineer should look at.
2. Write the details down
Note the exact code first, together with your boiler's make and model, and what happened just before it appeared. It means the engineer arrives better prepared.
Don't open your boiler casing, and leave anything on the gas side alone. If you smell gas, leave the property and ring the National Gas Emergency Service on 0800 111 999.
When it's a job for us
A pressure that creeps back up needs an engineer.