The meaning of CE 207
CE 207 tells you the heating circuit has lost pressure. Worcester says the system should normally read between 1 and 1.5 bar when cool. On some newer Worcester models with a text display, low pressure is shown as a number with a description instead. You may well be able to clear this one yourself.
Always cross-check with the manual for your exact model. We're out across Rugby most days, from Clifton upon Dunsmore to Newbold on Avon and Houlton.
Typical causes
In our experience, and in the manufacturer's own guidance, the usual causes are:
- An expansion vessel that needs recharging
- The pressure relief valve discharging
- Pressure lost after bleeding radiators
- A slow leak somewhere on the system
Homeowner checks
1. Look at the pressure
With the heating off and your boiler cool, look at the pressure reading on your boiler. The majority of boilers want roughly 1 to 1.5 bar when cold, or whatever figure your manual gives. If it reads below 1 bar, you can normally refill it yourself using the filling loop, a short braided hose or a built-in key under your boiler. Open the taps slowly, watch the needle rise, then close them firmly once you reach the right pressure. If the pressure drops again within days, water is escaping somewhere and that's a job for an engineer.
2. Use the reset button, once
Follow the reset steps in your manual: on a Greenstar, hold it for around five seconds. Give it a few minutes to run through its start-up. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.
Don't open your boiler casing, and leave anything on the gas side alone. If you smell gas, leave the property and ring the National Gas Emergency Service on 0800 111 999.
When it's a job for us
If CE 207 keeps returning, water is getting out and an engineer should find where: look for damp patches and the outside relief pipe, then book an engineer.
If it won't clear, call 01788 851272 or book a visit online. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
See also
- Vaillant F.22 – low water pressure
- Baxi E119 – low water pressure
- Baxi E117 – water pressure too high
- All Worcester Bosch codes