The meaning of D5
D5 is shown by floor-standing Greenstar boilers when the condensate pump can't clear water. A frozen pipe outside can trigger it. Other models may use D5 differently, so look at the manual for yours. Some causes are simple to rule out, others need a Gas Safe engineer.
Always cross-check with the manual for your exact model. If your boiler is still under the builder's or manufacturer's warranty, as many newer homes at Houlton may be, check with them before booking a repair.
Typical causes
Possible causes include:
- A failed or blocked condensate pump
- A kinked or blocked condensate hose
- A frozen or blocked external condensate pipe
Homeowner checks
1. In freezing weather, look at the condensate pipe
The condensate pipe is the plastic pipe that carries water from your boiler to a drain, regularly outside. When it freezes your boiler regularly gurgles and stops. As long as the pipe is low down and safe to reach, thaw it with a warm cloth or warm (not boiling) water, then reset your boiler. Don't try this at height.
2. Try a single reset
Press the reset button as your user instructions describes: Worcester Bosch asks you to hold it for about five seconds. Give it a few minutes to run through its start-up. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.
3. Write the details down
Make a note of the code before resetting, together with your boiler's make and model, and whether it happened on heating, hot water or both. That information helps us diagnose faster.
Anything behind the casing, and any gas or flue work, must be left to a Gas Safe engineer. If there's a smell of gas, ring 0800 111 999 from outside.
When it's a job for us
When thawing doesn't help, the condensate pump needs cleaning or replacing: that means opening your boiler, which is engineer work.
If it won't clear, call 01788 851272 or book a visit online. Lines are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.