The meaning of EA 229
With EA 229, your boiler lit normally and then the flame signal dropped out. Look first at drainage and the flue. Some causes are simple to rule out, others need a Gas Safe engineer.
Always cross-check with the manual for your exact model. Village homes around Dunchurch and Clifton upon Dunsmore can be more exposed in a cold snap, so frozen condensate pipes crop up there every winter.
Typical causes
In our experience, and in the manufacturer's own guidance, the usual causes are:
- A worn flame-sensing electrode
- Strong wind or an obstruction at the flue terminal
- A frozen or blocked condensate pipe or trap
- An interruption in the gas supply
Homeowner checks
1. Look at the condensate pipe outside
The condensate pipe is the plastic pipe that carries water from your boiler to a drain, regularly outside. If it's frozen, your boiler may gurgle and then lock out. As long as the pipe is low down and safe to reach, thaw it with warm water, never boiling, poured slowly along the pipe, then reset your boiler. Leave pipes at height to an engineer.
2. Glance at the flue terminal
Be sure the flue terminal outside isn't covered or blocked. Looking is fine; adjusting the flue is not: any damage or blockage is a job for a Gas Safe engineer.
3. Rule out the gas supply
Try the gas hob, if you have one. On a prepayment meter, look at the credit and any emergency credit, as running out is a common cause of ignition lockouts. Don't touch any gas pipes or valves on or inside your boiler. If you smell gas, get everyone out and ring 0800 111 999.
4. Use the reset button, once
Use the reset button on the front panel: on a Greenstar, hold it for around five seconds. Allow a little time for your boiler to try again. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.
Never remove your boiler casing or touch the gas valve, gas pipes or flue. Smell gas? Get outside and ring 0800 111 999.
When it's a job for us
Repeat EA 229 lockouts call for an engineer: the trap sits inside the casing, which is engineer territory.
Ring 01788 851272 with the code and your boiler's model, or use our enquiry form. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
See also
- Worcester Bosch EA 227 – no flame detected at ignition
- Vaillant F.29 – flame loss during operation
- Worcester Bosch D5 – condensate pump fault (floor-standing)
- All Worcester Bosch codes
- Boiler breakdown help in Rugby